Published June 1, 1996 | Version v1
Journal article

A streamer tube detector for operation at high rates in the CPLEAR experiment at CERN

Description

The design and instrumentation of a streamer tube detector for operation in the high rate environment of the CPLEAR experiment at CERN is described. A study of gas mixtures for use in the streamer tube is discussed. The final mixture of 46% argon, 50% isobutane, 4% methylal and 0.01% freon produces an axial resolution of 1.5 cm with an efficiency of 98% per layer. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
374
Journal Issue
3
Journal Page Range
p. 303-308.
ISSN
0168-9002
CODEN
NIMAER