Published October 1977
| Version v1
Report
Restricted
Initial test experience with the Texas A and M EBIS
Creators
- 1. Texas Agricultural and Mechanical Univ., College Station (USA). Cyclotron Inst.
Description
A 20 cm EBIS with an axial field precision sufficient to yield 99.8% transmission of a 1 mm beam through 3 mm drift tubes has been constructed. Operated at 2.4 kV and 0.25 amp a total contained charge of up to 5 x 109 electronic charges or approximately 50% space charge compensation is extracted in approximately 20 μs for containment periods from 1 to 5 ms. Improvement of the trap vacuum and extraction optics is necessary for useful currents of fully-stripped carbon and nitrogen beams. (orig.)
Abstract (German)
Es wurde ein 20cm EBIS mit einer Genauigkeit des axialen Feldes konstruiert, die ausreicht, um fuer einen 1mm Strahl eine Transmission durch 3 mm Driftroehren von 99,8% zu gewaehrleisten. Unter 2,4 kV und 0,25 amp wird eine gesamte enthaltene Ladung von bis zu 5 x 109 Elektronenladungen oder ca. 50% Raumladungskompensation in ca. 20 μs extrahiert, wobei die Behaelterperioden zwischen 1 ms und 5 ms liegen. Fuer brauchbare Stroeme von vollstaendig gestrippten Kohlenstoff- und Stickstoff-Strahlen ist eine Verbesserung des Einfangsvakuums und der Extraktionsoptik noetig. (orig.)
Files
Additional details
Publishing Information
- Imprint Title
- Workshop on EBIS and related topics
- Journal Page Range
- p. 21-26.
- Report number
- GSI-P--3-77
Conference
- Title
- Workshop on EBIS and related topics.
- Dates
- 15 - 16 Jun 1977.
- Place
- Darmstadt, Germany, F.R.
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 9386490
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM CURRENTS; BEAM EXTRACTION; BEAM OPTICS; DRIFT TUBES; ELECTRON BEAM ION SOURCES; HEAVY IONS; ION BEAMS
- Descriptors DEC
- BEAMS; CHARGED PARTICLES; CURRENTS; ION SOURCES; IONS
Optional Information
- Notes
- 4 figs.; 4 refs.
- Secondary number(s)
- AED-Conf--77-427-005.