Published October 1977 | Version v1
Report Restricted

Initial test experience with the Texas A and M EBIS

  • 1. Texas Agricultural and Mechanical Univ., College Station (USA). Cyclotron Inst.

Description

A 20 cm EBIS with an axial field precision sufficient to yield 99.8% transmission of a 1 mm beam through 3 mm drift tubes has been constructed. Operated at 2.4 kV and 0.25 amp a total contained charge of up to 5 x 109 electronic charges or approximately 50% space charge compensation is extracted in approximately 20 μs for containment periods from 1 to 5 ms. Improvement of the trap vacuum and extraction optics is necessary for useful currents of fully-stripped carbon and nitrogen beams. (orig.)

Abstract (German)

Es wurde ein 20cm EBIS mit einer Genauigkeit des axialen Feldes konstruiert, die ausreicht, um fuer einen 1mm Strahl eine Transmission durch 3 mm Driftroehren von 99,8% zu gewaehrleisten. Unter 2,4 kV und 0,25 amp wird eine gesamte enthaltene Ladung von bis zu 5 x 109 Elektronenladungen oder ca. 50% Raumladungskompensation in ca. 20 μs extrahiert, wobei die Behaelterperioden zwischen 1 ms und 5 ms liegen. Fuer brauchbare Stroeme von vollstaendig gestrippten Kohlenstoff- und Stickstoff-Strahlen ist eine Verbesserung des Einfangsvakuums und der Extraktionsoptik noetig. (orig.)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Workshop on EBIS and related topics
Journal Page Range
p. 21-26.
Report number
GSI-P--3-77

Conference

Title
Workshop on EBIS and related topics.
Dates
15 - 16 Jun 1977.
Place
Darmstadt, Germany, F.R.

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
9386490
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM CURRENTS; BEAM EXTRACTION; BEAM OPTICS; DRIFT TUBES; ELECTRON BEAM ION SOURCES; HEAVY IONS; ION BEAMS
Descriptors DEC
BEAMS; CHARGED PARTICLES; CURRENTS; ION SOURCES; IONS

Optional Information

Notes
4 figs.; 4 refs.
Secondary number(s)
AED-Conf--77-427-005.