Initial exploration of coronary stent image subtraction using dual-layer spectral CT
Creators
- 1. Department of Radiology, Ruijin Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai (China)
- 2. Department of Cardiology, Ruijin Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai (China)
- 3. Philips Healthcare, Shanghai (China)
Description
This study aimed to investigate the feasibility of coronary stent image subtraction using spectral tools derived from dual-layer spectral computed tomography (CT). Forty-three patients (65 stents) who underwent coronary CT angiography using dual-layer spectral CT were included. Conventional, 50-keV (kilo electron-volt), 100-keV, and virtual non-contrast (VNC) images were reconstructed from the same cardiac phase. Stents were subtracted on VNC images from conventional (conv), 100-keV (100-keV), and 50-keV (50-keV) images. The in-stent lumen diameters were measured on subtraction, conventional, and 100-keV images. Subjective evaluation of reader confidence and subtractive quality was evaluated. Friedman tests were performed to compare in-stent lumen diameters and subjective evaluation among different images. Correlation between stent diameter and subjective evaluation was expressed as Spearman's rank correlation coefficient (r). The diagnostic accuracy was assessed according to invasive coronary angiography (ICA) performed in 11 patients (20 stents). In-stent lumen diameters were significantly larger on subtraction images than those on conventional and 100-keV images (p < 0.05). Higher reader confidence was found on 100-keV, conv, 100-keV, and 50-keV images compared with conventional images (p < 0.05). Subtractive quality of 100-keV images was better than that of conv images (p = 0.037). A moderate-to-strong correlation between stent diameter and subjective evaluation was found (r = 0.527~0.790, p < 0.05). Higher specificity, positive predictive value, and negative predictive value of subtraction images were shown by ICA results. Subtraction images derived from dual-layer spectral CT enhanced in-stent lumen visibility and could potentially improve diagnostic performance for evaluating coronary stents.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-018-5990-1Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 29
- Journal Issue
- 8
- Journal Page Range
- p. 4239-4248
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 51004690
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ATTENUATION; BIOMEDICAL RADIOGRAPHY; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CORONARIES; CORRECTIONS; CORRELATIONS; DIAGNOSIS; EFFECTIVE RADIATION DOSES; IMAGE PROCESSING; KEV RANGE 10-100; PERFORMANCE; SPECIFICITY; SURGICAL MATERIALS; VISIBILITY
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DOSES; ENERGY RANGE; EVALUATION; KEV RANGE; MATERIALS; MEDICAL SUPPLIES; MEDICINE; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIATION DOSES; RADIOLOGY; TOMOGRAPHY