There is a newer version of the record available.

Published 2024 | Version v1
Journal article

Localization of contrast-enhanced breast lesions in ultrafast screening MRI using deep convolutional neural networks

  • 1. Department of Radiation Oncology, and Data Science Center in Health (DASH), Machine Learning Lab, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen (Netherlands)
  • 2. Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen (Netherlands)
  • 3. School of Engineering, Artificial Intelligence and Biomedical Image Analysis Lab, Westlake University, No.18 Shilongshan, Road Cloud Town, Xihu District, 310024, Hangzhou, Zhejiang (China)
  • 4. Faculty of Medical Sciences, University of Groningen, and Institute of Diagnostic Accuracy, Wiersmastraat 5, 9713 GH, Groningen (Netherlands)

Description

To develop a deep learning-based method for contrast-enhanced breast lesion detection in ultrafast screening MRI. A total of 837 breast MRI exams of 488 consecutive patients were included. Lesion's location was independently annotated in the maximum intensity projection (MIP) image of the last time-resolved angiography with stochastic trajectories (TWIST) sequence for each individual breast, resulting in 265 lesions (190 benign, 75 malignant) in 163 breasts (133 women). YOLOv5 models were fine-tuned using training sets containing the same number of MIP images with and without lesions. A long short-term memory (LSTM) network was employed to help reduce false positive predictions. The integrated system was then evaluated on test sets containing enriched uninvolved breasts during cross-validation to mimic the performance in a screening scenario. In five-fold cross-validation, the YOLOv5x model showed a sensitivity of 0.95, 0.97, 0.98, and 0.99, with 0.125, 0.25, 0.5, and 1 false positive per breast, respectively. The LSTM network reduced 15.5% of the false positive prediction from the YOLO model, and the positive predictive value was increased from 0.22 to 0.25. A fine-tuned YOLOv5x model can detect breast lesions on ultrafast MRI with high sensitivity in a screening population, and the output of the model could be further refined by an LSTM network to reduce the amount of false positive predictions. The proposed integrated system would make the ultrafast MRI screening process more effective by assisting radiologists in prioritizing suspicious examinations and supporting the diagnostic workup.

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology (Internet)
Journal Volume
34
Journal Issue
3
Journal Page Range
p. 2084-2092
ISSN
1432-1084
CODEN
EURAE3