Published 1989 | Version v1
Report Open

The status of RandD for the relativistic heavy ion collider at Brookhaven

Description

Formal development of the Relativistic Heavy Ion Collider (RHIC) has been funded for the past three years. Prototype superconducting magnets and cryostats have been tested. Detailed designs have been prepared for the arc sections, the insertion regions and injection and ejection systems. The rf system has undergone significant revisions in order to enhance the experimental capability of RHIC. Progress has been made with the design of detectors. We are putting in place a management information system in anticipation of an expeditious start of construction. 20 refs., 2 figs., 3 tabs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02 - OSTI; 3 as DE89010574.

Files

20060644.pdf

Files (271.7 kB)

Name Size Download all
md5:12e7618a168109acb13063d948b7ef43
271.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
BNL--41829

Conference

Title
13. particle accelerator conference.
Dates
20-23 Mar 1989.
Place
Chicago, IL (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20060644
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BROOKHAVEN RHIC; COST; DETECTION; RF SYSTEMS; SPECIFICATIONS; SUPERCONDUCTING MAGNETS
Descriptors DEC
ACCELERATORS; ELECTRICAL EQUIPMENT; ELECTROMAGNETS; EQUIPMENT; HEAVY ION ACCELERATORS; MAGNETS; STORAGE RINGS; SUPERCONDUCTING DEVICES

Optional Information

Notes
Paper copy only, copy does not permit microfiche production.
Secondary number(s)
CONF-890335--67.