Published May 1976 | Version v1
Journal article

An analytical method of 6Li, 10B and 113Cd concentrations in aqueous solutions using 14MeV neutron generator

  • 1. Kumamoto Univ. (Japan). Faculty of Engineering

Description

Transmissions of 14 MeV neutrons for the samples were determined from the radioactivities of Dy2O3 targets. Semi-log plots of transmissions against the concentrations fell on straight lines. From the slope of the lines, detection limits and standard deviations were calculated, and were found to be 5 x 10-3, 2 x 10-3, 6 x 10-4M and 5.2, 5.2, 4.5%. A plot of the slope against absorption cross sections of the isotopes for thermal neutrons also fell on a straight line. The neutron transmission for aqueous solution samples was formulated. From the results of interference by other elements for the analysis, the permitted concentrations in systems of 10B-Cl and 113Cd-Hg, were 1.5 M of Cl and 0.04 M of Hg, respectively. In the systems of 6Li-Na and 113Cd-Zn, interference was not observed. (auth.)

Additional details

Publishing Information

Journal Title
RADIOISOTOPES
Journal Volume
25
Journal Issue
5
Series
Radioisotopes (Tokyo).
Journal Page Range
255-259
ISSN
1884-4111

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent