Published August 14, 2012 | Version v1
Report

Development of Electronics for the ATF2 Interaction Point Region Beam Position Monitor

Description

Nanometer resolution beam position monitors have been developed to measure and control beam position stability at the interaction point region of ATF2. The position of the beam has to be measured to within a few nanometers at the interaction point. In order to achieve this performance, electronics for the low-Q IP-BPM was developed. Every component of the electronics have been simulated and checked on the bench and using the ATF2 beam. We will explain each component and define their working range. Then, we will show the performance of the electronics measured with beam signal. ATF2 is a final focus test beam line for ILC in the framework of the ATF international collaboration. The new beam line was constructed to extend the extraction line at ATF, KEK, Japan. The first goal of ATF2 is the acheiving of a 37 nm vertical beam size at focal point (IP). The second goal is to stabilize the beam at the focal point at a few nanometer level for a long period in order to ensure the high luminosity. To achieve these goals a high resolution IP-BPM is essential. In addition for feedback applications a low-Q system is desirable.

Availability note (English)

Available from http://www.slac.stanford.edu/cgi-wrap/getdoc/slac-pub-15217.pdf; http://www.slac.stanford.edu/cgi-wrap/pubpage?slac-pub-15217.html; PURL: https://www.osti.gov/servlets/purl/1048645/

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
SLAC-PUB--15217

Conference

Title
1. International Particle Accelerator Conference
Acronym
IPAC 2010
Dates
23-28 May 2010
Place
Kyoto (Japan)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
43127984
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; BEAM POSITION; FEEDBACK; LUMINOSITY; MONITORS; PERFORMANCE; RESOLUTION; STABILITY
Descriptors DEC
MEASURING INSTRUMENTS; OPTICAL PROPERTIES; PHYSICAL PROPERTIES

Optional Information

Contract/Grant/Project number
AC02-76SF00515
Notes
Conf.Proc.C100523:MOPE035,2010
Funding organization
US DOE Office of Science (United States)