Published 2005 | Version v1
Journal article

Physical modelling of the composting environment: A review. Part 2: Simulation performance

  • 1. Department of Civil Engineering, University of Canterbury, Private Bag 4800, Christchurch (New Zealand)

Description

This paper reviews previously published heat balance data for experimental and full-scale composting reactors, and then presents an evaluation of the simulation performance of laboratory and pilot-scale reactors, using both quantitative and qualitative temperature profile characteristics. The review indicates that laboratory-scale reactors have typically demonstrated markedly different heat balance behaviour in comparison to full-scale systems, with ventilative heat losses of 36-67%, and 70-95% of the total flux, respectively. Similarly, conductive/convective/radiative (CCR) heat losses from laboratory reactors have been reported at 33-62% of the total flux, whereas CCR losses from full-scale composting systems have ranged from 3% to 15% of the total. Full-scale windrow temperature-time profiles from the literature were characterised by the present authors. Areas bounded by the curve and a 40 deg. C baseline (A 40) exceeded 624 deg. C. days, areas bounded by the curve and a 55 deg. C baseline (A 55) exceeded 60 deg. C days, and times at 40 and 55 deg. C were >46 days and >24 days, respectively, over periods of 50-74 days. For forced aeration systems at full scale, values of A 40 exceeded 224 deg. C days, values of A 55 exceeded 26 deg. C days, and times at 40 and 55 deg. C were >14 days and >10 days, respectively, over periods of 15-35 days. Values of these four parameters for laboratory-scale reactors were typically considerably lower than for the full-scale systems, although temperature shape characteristics were often similar to those in full-scale profiles. Evaluation of laboratory-, pilot- and full-scale profiles from systems treating the same substrate showed that a laboratory-scale reactor and two pilot-scale reactors operated at comparatively high aeration rates poorly simulated full-scale temperature profiles. However, the curves from two moderately insulated, self-heating, pilot-scale reactors operated at relatively low aeration rates appeared to closely replicate full-scale temperature profiles. The importance of controlling aeration rates and CCR losses is discussed and further work suggested in order to investigate the links between simulation of the composting environment and process performance

Additional details

Identifiers

DOI
10.1016/j.wasman.2005.01.016;
PII
S0956-053X(05)00047-4;

Publishing Information

Journal Title
Waste Management
Journal Volume
25
Journal Issue
5
Journal Page Range
p. 501-509
ISSN
0956-053X
CODEN
WAMAE2

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38043182
Subject category
S54: ENVIRONMENTAL SCIENCES;
Descriptors DEI
AERATION; COMPOSTING; HEAT LOSSES; HEATING; PERFORMANCE; SIMULATION; SUBSTRATES
Descriptors DEC
ENERGY LOSSES; ENERGY TRANSFER; HEAT TRANSFER; LOSSES; MANAGEMENT; PROCESSING; WASTE MANAGEMENT; WASTE PROCESSING