CAMAC differential pulse discriminator-counter

  • 1. Tomskij Politekhnicheskij Inst. (USSR). Inst. Yadernoj Fiziki, Ehlektroniki i Avtomatiki

Description

Differential pulse discriminator-counter for Moessbauer spectrometer is described. Input pulse setting into the channel is performed according to the following algorithm: the pulse is transmitted to the channel depending on the fact whether the preceding pulse has got to the discrimination window or not. The circuit does not contain delay lines, taking into account the delay of a signal from the upper level discriminator in relation to the lower level discriminator signal, which is connected with input pulse rise finite time, which in turn allows one to reduce the discriminator dead time up to the operation time of threshold circuits. The pulse counting rate is 150 MHz, input signal amplitude is ±3 V, dead time is 6 ns, delay time from input to output is 14 ns. The unit is made in CAMAC system

Additional details

Additional titles

Original title (Russian)
Дифференциальный дискриминатор-счетчик импульсов в системе KAMAK

Publishing Information

Journal Title
Prib. Tekh. Ehksp.
Journal Issue
no.4
Series
Prib. Tekh. Ehksp.
ISSN
0032-8162
CODEN