The possibility of water vapor leaks across the wall of one or more of the heat exchanger tubes in the steam generator constitutes one of the important problems of safety of the Fast Breeder Reactors cooled by sodium. The jet thus formed can, in fact, destroy the neighbouring tubes. The hydrodynamic, chemical and thermal factors play an important role in this phenomenon and only the last-mentionned will be studied here. The use of the integral method of analysis, complemented by an experimental study, shows that the temperature profiles are Gaussian; if the maximum temperature is less than that of the boiling point of sodium