Published 1978 | Version v1
Journal article

Gamma flaw detectors for radiographic control of welded joint quality under mounting conditions

Description

Main characteristics are presented of gamma flaw detector models used for radiographic control of the quality of welded steel and pipeline joints during assembly. Specially developed experimental models, operating with 75Se, 90Sr, 170Tm, 137Cs and 192Ir sources are considered. The new instruments have been made on a single structural base, which creates a foundation for standardizing individual units of radiation heads, manual control panels, containers, exterior packings, devices and accessories, maintenance techniques, and repair techniques. They are distinguished by small sizes and weight, possibility of using a set of radiation sources ensuring control of 3-40 mm thick joints, and reliable protection. Special devices permit to reduce 2-3-folds the time needed for installing and orienting the flaw detectors. The expected economic effect from implementation of the new gamma flaw detectors into industry will amount to 1.5-10.0 thousand roubles per annum for one detector at approximate cost of each detector equal to 3.5-6.0 thousand roubles

Additional details

Additional titles

Original title (Russian)
Гамма-дефектоскопы для радиографического контроля качества сварных соединений в монтажных условиях

Publishing Information

Journal Title
Tr., Vses. Nauchno-Issled. Inst. Radiats. Tekh.
Journal Issue
no.16
Series
Tr., Vses. Nauchno-Issled. Inst. Radiats. Tekh.