Published 2005 | Version v1
Journal article

Shielding for a cyclotron used for medical isotope production in China

  • 1. The Univ. of Tennessee, Knoxville, TN 37996 (United States)
  • 2. CTI Inc., 810 Innovation Drive, Knoxville, TN 37932 (United States)

Description

Monte Carlo and discrete ordinate calculations have been performed to determine the doses at several locations in a positron emission tomography (PET) facility in China, where the radiation source is a cyclotron that is used for the production of the isotopes necessary for PET scans. The energy-dependent neutron source term is obtained by calculations using the ALICE code, and is interpolated for input to Monte Carlo and discrete ordinate calculations. The building that houses the cyclotron has a labyrinth of walls to minimise dose to operators and to other occupants of the building. Unbiased Monte Carlo calculations did not converge after more than one week of CPU time, whereas direction biasing alone resulted in convergence in several days. A study of several biasing techniques indicated that about a factor of 3 in computational efficiency is obtained using evaluated biasing methods. The use of adjoint fluxes for biasing Monte Carlo calculations can improve computational efficiencies by one or two orders of magnitude for some problems. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/nci206

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
115
Journal Issue
1-4
Journal Page Range
p. 415-419
ISSN
0144-8420

Conference

Title
10. International Conference on Radiation Shielding, and 13. ANS Topical Meeting on Radiation Protection and Shielding - ICRS-10/RPS 2004
Dates
9-14 May 2004
Place
Funchal, Madeira Island (Portugal)

Optional Information

Notes
4 refs