Published September 1990
| Version v1
Journal article
Effect of intensifying screens to subject contrast
- 1. Junior College of Allied Health Sciences, Korea University, Seoul (Korea, Republic of)
- 2. Inchon Junior Nursing College and Allied Health Sciences, Incheon (Korea, Republic of)
- 3. Dongnam Health Junior College, Suwon (Korea, Republic of)
Description
It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows ; 1. In the same object radiography, use acquired the difference of the object contrast between LT-II(CaWO4 system) and G4(Gd system) screens. 2. object contrast more decreased in Gd system screen than CaWO4 and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society of Radiological Technology
- Journal Volume
- 13
- Journal Issue
- 2
- Series
- 6 refs, 3 figs, 2 tabs
- Journal Page Range
- p. 27-30
- ISSN
- 1226-2854
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 40075231
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CONTRAST MEDIA; IMAGES; SCREENS; TUBES