Published February 1996 | Version v1
Report Open

Evaluation of peaking factors uncertainty for CASMO-3

  • 1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Description

This document evaluates the pin-to-box factor uncertainty based on using the CASMO-3 with 40-group J-library. Five CE criticals performed by Westinghouse, two by B and W and four RPI criticals were analyzed, using cross sections by CASMO-3. DOT was used for the core calculation. THis is one hof series of efforts to verify ADONIS procedure which is a new core design package under development by KAERI. The expected outcome of this analysis is CASMO-3 pin peak uncertainty applicable to CE type fuel assembly design. The evaluated uncertainty of peaking factors for CASMO-3 was 1.863%. 21 tabs., 23 figs., 12 refs. (Author) .new

Availability note (English)

MF available from INIS under the Report Number.

Files

27063156.pdf

Files (1.6 MB)

Name Size Download all
md5:ca9ad114c8c4e2ed750e2a8897622165
1.6 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
70 p.
Report number
KAERI/TR--628/96

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
27063156
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Descriptors DEI
BENCHMARKS; COMPUTER CODES; CRITICALITY; DATA COVARIANCES; GROUP CONSTANTS; NEUTRON DENSITY; POWER DENSITY; REACTOR CORES
Descriptors DEC
CROSS SECTIONS; REACTOR COMPONENTS