Published January 1, 2017 | Version v1
Report

Centrifugal Contactor Efficiency Measurements

  • 1. Idaho National Lab. (INL), Idaho Falls, ID (United States)

Description

The contactor efficiency of a 2-cm acrylic centrifugal contactor, fabricated by ANL using 3D printer technology was measured by comparing a contactor test run to 5-min batch contacts. The aqueous phase was ~ 3 ppm depleted uranium in 3 M HNO3, and the organic phase was 1 M DAAP/dodecane. Sampling during the contactor run showed that equilibrium was achieved within < 3 minutes. The contactor efficiency at equilibrium was 95% to 100 %, depending on flowrate.

Availability note (English)

Available from https://inldigitallibrary.inl.gov/sites/sti/sti/7323678.pdf; PURL: http://www.osti.gov/servlets/purl/1369627/

Additional details

Publishing Information

Imprint Pagination
10 p.
Report number
INL/EXT--17-41056

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
48086331
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
COMPARATIVE EVALUATIONS; DEPLETED URANIUM; DODECANE; EFFICIENCY; EXTRACTION APPARATUSES
Descriptors DEC
ACTINIDES; ALKANES; ELEMENTS; EQUIPMENT; EVALUATION; HYDROCARBONS; METALS; ORGANIC COMPOUNDS; SEPARATION EQUIPMENT; URANIUM

Optional Information

Contract/Grant/Project number
AC07-05ID14517
Funding organization
USDOE Office of Nuclear Energy - NE (United States)
Secondary number(s)
OSTIID--1369627