Description
The contactor efficiency of a 2-cm acrylic centrifugal contactor, fabricated by ANL using 3D printer technology was measured by comparing a contactor test run to 5-min batch contacts. The aqueous phase was ~ 3 ppm depleted uranium in 3 M HNO3, and the organic phase was 1 M DAAP/dodecane. Sampling during the contactor run showed that equilibrium was achieved within < 3 minutes. The contactor efficiency at equilibrium was 95% to 100 %, depending on flowrate.
Availability note (English)
Available from https://inldigitallibrary.inl.gov/sites/sti/sti/7323678.pdf; PURL: http://www.osti.gov/servlets/purl/1369627/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- INL/EXT--17-41056
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 48086331
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- COMPARATIVE EVALUATIONS; DEPLETED URANIUM; DODECANE; EFFICIENCY; EXTRACTION APPARATUSES
- Descriptors DEC
- ACTINIDES; ALKANES; ELEMENTS; EQUIPMENT; EVALUATION; HYDROCARBONS; METALS; ORGANIC COMPOUNDS; SEPARATION EQUIPMENT; URANIUM