Automatic alignment of cranial CT examinations to the anterior commissure/posterior commissure (ACPC) reference plane for reliable interpretation and quality assurance
- 1. University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology (Germany)
Description
Alignment of cranial CT scans (cCTs) to a common reference plane simplifies anatomical-landmark-based orientation and eases follow-up assessment of intracranial findings. We developed and open sourced a fully automated system, which aligns cCTs to the Anterior Commissure/Posterior Commissure (ACPC) line and exports the results to the PACS. FMRIB's Linear Image Registration Tool (FLIRT) with an ACPC-aligned atlas is used in the alignment step. Five mm mean slabs are generated with the top non-air slice as the starting point. For evaluation, 301 trauma cCTs from the CQ500 dataset were processed. In visual comparison with the respective ACPC-aligned atlas, all were successfully aligned. Image quality (IQ) and ease of identification of the central sulcus (CS) were rated on a Likert scale (5 = excellent IQ/immediate CS identification). The median IQ was 4 (range: 2–4) in the original series and 5 (range: 4–5) in the ACPC-aligned series (p < 0.0001). The CS was more easily identified after fatbACPC (original scans: 4 (range: 2–5); ACPC-aligned: 5 (range: 4–5); p < 0.0001). The mean rotation to achieve alignment was |X| = 6.4 ± 5.2° ([–X,+X] = –26.8°–24.2°), |Y| = 2.1 ± 1.7° ([-Y,+Y] = –8.7°–9.8°), and |Z| = 3.1 ± 2.4° ([–Z,+Z] = –14.3°–12.5°). The developed system can robustly and automatically align cCTs to the ACPC line. Degrees of deviation from the ideal alignment could be used for quality assurance.
Availability note (English)
Available from: http://dx.doi.org/10.1055/a-1167-8368Additional details
Identifiers
- DOI
- 10.1055/a-1167-8368;
Publishing Information
- Journal Title
- RoeFo - Fortschritte auf dem Gebiet der Roentgenstrahlen und der bildgebenden Verfahren
- Journal Volume
- 193
- Journal Issue
- 1
- Journal Page Range
- p. 61-67
- ISSN
- 1438-9029
- CODEN
- RFGNDO
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 52025340
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALIGNMENT; AUTOMATION; BRAIN; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; DATASETS; HEAD; IMAGE PROCESSING; INJURIES; QUALITY ASSURANCE; RELIABILITY
- Descriptors DEC
- BODY; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; DOCUMENT TYPES; EVALUATION; MANAGEMENT; NERVOUS SYSTEM; ORGANS; PROCESSING; QUALITY MANAGEMENT; TOMOGRAPHY