Published April 2009
| Version v1
Journal article
Development of measurement system for radiation effect on A/D converter
- 1. Northwest Inst. of Nuclear Technology, Xi'an (China)
Description
A measurement system for radiation effects on analog-to-digital (A/D) converter based on histogram method was developed. Testing principle, system composition, control flow and systemic function were described. Total dose effects experiment of 12 bit AD574AJD using the system was carried out on 60Co source to verify its effectivity. The results show that the static parameters and functional parameters gained by the system can accurately reflect the damage effect of the devices under test. So the system is a well test bench for radiation effects on A/D converter. (authors)
Additional details
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 43
- Journal Issue
- 4
- Journal Page Range
- p. 368-372
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 42073255
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ANALOG-TO-DIGITAL CONVERTERS; COBALT 60; CONTROL; DAMAGE; DOSES; EQUIPMENT; FUNCTIONS; PERFORMANCE TESTING; RADIATION EFFECTS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; COBALT ISOTOPES; ELECTRONIC EQUIPMENT; EQUIPMENT; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; RADIOISOTOPES; TESTING; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 4 figs., 6 refs.