Published April 1980 | Version v1
Journal article

Neutron spectrometry using moderating spheres. II

  • 1. Ustav Jaderneho Vyzkumu CSKAE, Rez (Czechoslovakia)
  • 2. Ceskoslovenska Akademie Ved, Prague. Ustav Dozimetrie Zareni

Description

Spheres of 5.1, 6.4, 7.6, 10.7, and 12.7 cm in diameter were used in cooperation with a semiconductor DTN-1 solid state track detector with 235U. The neutron spectrum was calculated using three different techniques, ie., the SPEC program seeking the solution as a linear combination of model spectra, the BONNER program based on the statistical control method, and the SAMD-ADT iteration program based on the SAND II algorithm. The spectra and the corresponding neutron flux densities in the region of 0.01 eV to 10 MeV were analysed and compared. (H.S.)

Part of:
Neutron spectrometry using moderating spheres. I

Additional details

Additional titles

Subtitle (English)
Spectrum in TR-0 reactor core
Original title (Czech)
Spektrometrie neutronu pomoci moderacnich sfer. II
Original subtitle (Czech)
Spektrum v aktivni zone reaktoru TR 0.

Publishing Information

Journal Title
Jad. Energ.
Journal Volume
26
Journal Issue
4
Series
Jad. Energ.
Journal Page Range
135-137
ISSN
0448-116X

Optional Information

Notes
For Part I see Jad. Energ. (Jan 1980) v. 26(1) p. 2-7.