A Comparison of retrospective radon gas measurement techniques carried out in the Serbian spa of Niska Banja

  • 1. ECE Laboratory, Vinca Institute of Nuclear Sciences, P. O. Box 522, 11001, Belgrade, (Serbia)
  • 2. Radiological Protection Institute of Ireland, 3, Clonskeagh Square, Dublin 4, (Ireland)
  • 3. SCK CEN, Boeretang 200, BE-2400 Mol, (Belgium)
  • 4. University College Dublin, Belfield, Dublin 4, (Ireland)
  • 5. Faculty of Natural Sciences, Department of Physics, University of Pristina, 29, Lole Ribara Str., 38220 Kosovska Mitrovica, (Serbia)
  • 6. Republic Hydro-Meteorological Institute of Serbia, 66, Kneza Viseslava Str., Belgrade, (Serbia)

Description

Indoor radon retrospective concentrations were obtained and compared using two radon measurement methods. Both methods rely on the measurement of the long-lived radon progeny 210Pb, collected either on the surfaces (surface trap technique), most frequently glass, or in a volume trap, usually sponge from furniture (volume trap technique). These techniques have been used to retrospectively estimate radon gas concentrations that have existed in dwellings in the past. The work presented here compares the results provided by the surface trap technique devised at the University College of Dublin, Ireland, and the volume trap technique devised at the Scientific Research Center, Mol, Belgium. The field campaign was carried out by the research team of the ECE Laboratory of the Vinca Institute of Nuclear Sciences at the spa of Niska Banja, identified as a region of Serbia with a high indoor radon and ground water radium and radon content. (author)

Availability note (English)

Also available online from http://ntrp.vinca.rs

Additional details

Identifiers

Publishing Information

Journal Title
Nuclear Technology and Radiation Protection
Journal Volume
24
Journal Issue
2
Journal Page Range
p. 94-99
ISSN
1451-3994

Optional Information

Notes
28 refs., 5 figs., 2 tabs.