Published July 1996
| Version v1
Journal article
Superconducting correction impulse magnets for the accelerator Nuclotron
- 1. Joint Inst. for Nuclear Research, Moscow (Russian Federation)
Description
The superconducting accelerator Nuclotron was put into operation at JINR, Dubna. The accelerator contains 112 multipole correction windings. Each four of them are assembled as a magnet block with an inner diameter of 132 mm. The winding has one or two layers from Nb-Ti multifilament conductor. The windings are impregnated with epoxy resin compound and glued on the tube coil with two-phase helium forced at 4.5 K. Each magnet has 100 A current leads without helium gas cooling. This very much simplifies the system of helium gas collection at the accelerator. All the magnets were tested and installed in the accelerator
Additional details
Publishing Information
- Journal Title
- IEEE Transactions on Magnetics
- Journal Volume
- 32
- Journal Issue
- 4Pt1
- Journal Page Range
- p. 2197-2199.
- ISSN
- 0018-9464
- CODEN
- IEMGAQ
Conference
- Title
- 14. international conference on magnet technology.
- Dates
- 11-16 Jun 1995.
- Place
- Tampere (Finland).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27075336
- Subject category
- S43: PARTICLE ACCELERATORS; S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCELERATORS; BEAM BENDING MAGNETS; BEAM OPTICS; CORRECTIONS; DESIGN; INSTALLATION; MULTIPOLES; ORBITS; PARTICLE BEAMS; SUPERCONDUCTING MAGNETS
- Descriptors DEC
- BEAMS; ELECTRICAL EQUIPMENT; ELECTROMAGNETS; EQUIPMENT; MAGNETS; SUPERCONDUCTING DEVICES
Optional Information
- Secondary number(s)
- CONF-950691--.