Published 2007 | Version v1
Journal article

Development of a neutron personal dose equivalent detector

  • 1. Nuclear Fuel Cycle Engineering Laboratories, Japan Atomic Energy Agency, 4-33 Tokai-mura, Ibaraki-ken 319-1194 (Japan)
  • 2. Fuji Electric Systems Co., Ltd., Fuji-cho, Hino, Tokyo 191-8502 (Japan)

Description

A new neutron-measuring instrument that is intended to measure a neutron personal dose equivalent, Hp(10) was developed. This instrument is composed of two parts: (1) a conventional moderator-based neutron dose equivalent meter and (2) a neutron shield made of borated polyethylene, which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP calculations so as to have response characteristics that would generally match both the energy and angular dependencies of Hp(10). This new instrument will be a great help in assessing the reference values of neutron Hp(10) during field testing of personal neutron dosemeters in workplaces and also in interpreting their readings. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncm054

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
126
Journal Issue
1-4
Journal Page Range
p. 261-264
ISSN
0144-8420

Conference

Title
10. International Symposium on Neutron Dosimetry - Progress in dosimetry of neutrons and light nuclei
Dates
12-16 Jun 2006
Place
Uppsala (Sweden)

Optional Information

Notes
14 refs