Description

In the design of transformer coupled preamplifier for large detector capacitances the transformer ratio is customarily made equal to the value which meets the capacitive matching condition. If, however, parallel noise as well as series noise external to the amplifying device are present, the optimum choice of the transformer ratio may differ substantially from the previous one. The paper aims at investigating the optimum transformer ratio with a quite general configuration of noise sources, yet sticking to the model of ideal transformer. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
257
Journal Issue
2
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
331-338
ISSN
0168-9002
CODEN
NIMAE

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
19013956
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
BACKGROUND NOISE; COUPLING; OPTIMIZATION; PREAMPLIFIERS; TRANSFORMERS
Descriptors DEC
AMPLIFIERS; ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; EQUIPMENT; NOISE