Published September 21, 2011 | Version v1
Journal article

Effects of proton escape on detection efficiency in thin scintillator elements and its consequences for optimization of fast-neutron imaging

  • 1. Division of Applied Nuclear Physics, Department of Physics and Astronomy, Uppsala University, Box 516, 751 20 Uppsala (Sweden)

Description

Plastic scintillators are commonly used for neutron detection in the MeV energy range, based on n-p scattering and the subsequent deposition of recoil proton's kinetic energy in the detector material. This detection procedure gives a quasi-rectangular energy deposition distribution for mono-energetic neutrons, extending from zero to the neutron energy. However, if the detector sensitive element (DSE) is small, the energy deposition may be incomplete due to the recoil proton escape. In the application of neutron imaging, here exemplified by fast-neutron tomography, two conflicting requirements have been identified: (1) thin DSEs are required to obtain high spatial resolution and (2) energy discrimination may be required to reduce the influence of neutrons being scattered into the DSEs, which generally occurs at lower energies. However, at small DSE widths, the reduction of energy deposition due to recoil proton escape may cause a significant decrease in detection efficiency when energy discrimination is applied. In this work, energy deposition distributions in small-size DSEs have been simulated for Deuterium-Deuterium (DD; 2.5 MeV) and Deuterium-Tritium (DT; 14.1 MeV) fusion neutrons. The intrinsic efficiency has been analyzed as a function of energy discrimination level for various detector widths. The investigations show that proton recoil escape causes a significant drop in intrinsic detection efficiency for thin DSEs. For DT neutrons, the drop is 10% at a width of 3.2 mm and 50% at a width of 0.6 mm, assuming an energy threshold at half the incident neutron energy. The corresponding widths for a DD detector are 0.17 and 0.03 mm, respectively. Finally, implications of the proton escape effect on the design of a fast-neutron tomography device for void distribution measurements at Uppsala University are presented. It is shown that the selection of DSE width strongly affects the instrument design when optimizing for image unsharpness.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2011.01.002

Additional details

Identifiers

DOI
10.1016/j.nima.2011.01.002;
PII
S0168-9002(11)00016-7;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
651
Journal Issue
1
Journal Page Range
p. 110-116
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
9. world conference on neutron radiography (The Big-5 on Neutron Radiography)
Acronym
WCNR-9
Dates
3-8 Oct 2010
Place
Kwa Maritane (South Africa)

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.