Published November 2012 | Version v1
Journal article

Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

  • 1. Imaging Science Institute, Tuebingen (Germany)
  • 2. Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela (Spain)
  • 3. University of Santiago de Compostela, Department of Particle Physics, Santiago de Compostela (Spain)
  • 4. Max Plank Institute for Intelligent Systems, Department of Empirical Inference, Tuebingen (Germany)
  • 5. Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany)
  • 6. Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany)
  • 7. Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany)
  • 8. cmi-experts GmbH, Zuerich (Switzerland)

Description

Clinical PET/MR acquisition protocols entail the use of MR contrast agents (MRCA) that could potentially affect PET quantification following MR-based attenuation correction (AC). We assessed the effect of oral and intravenous (IV) MRCA on PET quantification in PET/MR imaging. We employed two MRCA: Lumirem registered (oral) and Gadovist registered (IV). First, we determined their reference PET attenuation values using a PET transmission scan (ECAT-EXACT HR+, Siemens) and a CT scan (PET/CT Biograph 16 HI-REZ, Siemens). Second, we evaluated the attenuation of PET signals in the presence of MRCA. Phantoms were filled with clinically relevant concentrations of MRCA in a background of water and 18F-fluoride, and imaged using a PET/CT scanner (Biograph 16 HI-REZ, Siemens) and a PET/MR scanner (Biograph mMR, Siemens). Third, we investigated the effect of clinically relevant volumes of MRCA on MR-based AC using human pilot data: a patient study employing Gadovist registered (IV) and a volunteer study employing two different oral MRCA (Lumirem registered and pineapple juice). MR-based attenuation maps were calculated following Dixon-based fat-water segmentation and an external atlas-based and pattern recognition (AT and PR) algorithm. IV and oral MRCA in clinically relevant concentrations were found to have PET attenuation values similar to those of water. The phantom experiments showed that under clinical conditions IV and oral MRCA did not yield additional attenuation of PET emission signals. Patient scans showed that PET attenuation maps are not biased after the administration of IV MRCA but may be biased, however, after ingestion of iron oxide-based oral MRCA when segmentation-based AC algorithms are used. Alternative AC algorithms, such as AT and PR, or alternative oral contrast agents, such as pineapple juice, can yield unbiased attenuation maps. In clinical PET/MR scenarios MRCA are not expected to lead to markedly increased attenuation of the PET emission signals. MR-based attenuation maps may be biased by oral iron oxide-based MRCA unless advanced AC algorithms are used. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00259-012-2190-0

Additional details

Identifiers

Publishing Information

Journal Title
European Journal of Nuclear Medicine and Molecular Imaging
Journal Volume
39
Journal Issue
11
Journal Page Range
p. 1756-1766
ISSN
1619-7070