Published April 2015 | Version v1
Journal article

Comparative evaluation of image quality in computed radiology systems using imaging plates with different usage time

  • 1. Hospital Sao Lucas (PUC-RS), Porto Alegre, RS (Brazil)
  • 2. Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica

Description

Computed Radiology (CR) systems use imaging plates (IPs) for latent image acquisition. Taking into account the quality control (QC) of these systems, imaging plates usage time is undetermined. Different recommendations and publications on the subject suggest tests to evaluate these systems. The objective of this study is to compare the image quality of IPs of a CR system, in a mammography service, considering the usage time and consistency of assessments. 8 IPs were used divided into two groups: the first group included 4 IPs with 3 years of use (Group A); the second group consisted of 4 new IPs with no previous exposure (Group B). The tests used to assess the IP's quality were: Uniformity, Differential Signal to Noise Ratio (SDNR), Ghost Effect and Figure of Merit (FOM). Statistical results show that the proposed tests are shown efficient in assessing the conditions of image quality obtained in CR systems in mammography and can be used as determining factors for the replacement of IP's. Moreover, comparing the two sets of IP, results led to the replacement of all the set of IP's with 3 years of use. This work demonstrates the importance of an efficient quality control, not only with regard to the quality of IP's used, but in the acquisition system as a whole. From this work, these tests will be conducted on an annual basis, already targeting as future work, monitoring the wear of IP's Group B and the creation of a baseline for analysis and future replacements. (author)

Availability note (English)

Available from http://www.rbfm.org.br/index.php/rbfm/article/view/345/v9n1p7

Additional details

Additional titles

Original title (Portuguese)
Avaliacao comparativa da qualidade da imagem em sistemas de radiologia computadorizada utilizando Imaging Plates com diferentes tempos de uso

Publishing Information

Journal Title
Revista Brasileira de Fisica Medica (Online)
Journal Volume
9
Journal Issue
1
Journal Page Range
p. 7-10
ISSN
1984-9001

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
47120063
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
COMPARATIVE EVALUATIONS; DATA ACQUISITION SYSTEMS; DIGITAL SYSTEMS; IMAGE PROCESSING; PLATES; QUALITY CONTROL; RADIOLOGY; STATISTICAL DATA
Descriptors DEC
CONTROL; DATA; EVALUATION; INFORMATION; MEDICINE; NUCLEAR MEDICINE; NUMERICAL DATA; PROCESSING