Published 1982 | Version v1
Report Restricted

Analysis of station blackout accidents for LWRs

Description

Station Blackout, the loss of all ac power in a nuclear power plant, is a Nuclear Regulatory Commission (NRC) unresolved safety issue. This paper summarizes station blackout accident sequence analyses conducted as part of a plan to resolve this issue. The results covered include: (a) core damage probabilities for four generic classes of plants, (b) factors most affecting these probabilities, (c) containment failure insights, and (d) examples of sensitivity analyses to cover other variations of plant design

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01 as DE82020987.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
10 p.
Report number
SAND--82-1930C

Conference

Title
International meeting on thermal nuclear reactor safety.
Dates
29 Aug - 2 Sep 1982.
Place
Chicago, IL (USA).

Optional Information

Secondary number(s)
CONF-820802--26.