Active interlock for storage ring insertion devices
Description
The insertion devices in the NSLS x-ray ring produce such intense photon beams that passive measures alone are not adequate to protect the vacuum chamber. An active interlock is used to prevent thermal damage from improperly steered electron beams. The interlock system measures the position of the electron beam on both sides of the insertion devices using pick-up electrodes and interrupts the rf if the beam moves outside a safe window. The interlock features redundant circuitry as well as an automatic testing procedure. 1 ref., 4 figs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02 - OSTI; 3 as DE89011901.Files
20066111.pdf
Files
(91.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:2ac79709314dcc7eb28e32cbe40c8854
|
91.9 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 4 p.
- Report number
- BNL--42673
Conference
- Title
- 13. particle accelerator conference.
- Dates
- 20-23 Mar 1989.
- Place
- Chicago, IL (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20066111
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DETECTION; ELECTRON BEAMS; LOGIC CIRCUITS; MICROPROCESSORS; NSLS; SPECIFICATIONS; STORAGE RINGS; TESTING; WIGGLER MAGNETS
- Descriptors DEC
- BEAMS; ELECTRONIC CIRCUITS; EQUIPMENT; LEPTON BEAMS; MAGNETS; MICROELECTRONIC CIRCUITS; PARTICLE BEAMS; RADIATION SOURCES; SYNCHROTRON RADIATION SOURCES
Optional Information
- Notes
- Paper copy only, copy does not permit microfiche production.
- Secondary number(s)
- CONF-890335--140.