Attenuated end-diastolic and end-systolic left ventricular counts which obtained from cardiac gated blood pool scan were corrected using experimentally calculated attenuation coefficient (μ=0.13/cm) and depth of center of left ventricle. This method was confirmed to be correct experimentally using phantom balloon. To compare the accuracy of attenuated and attenuation- corrected left ventricular volume measurement authors studied 10 patients with ischemic heart disease who underwent both gater blood pool sca and X-ray contrast ventriculography within a week. The attenuated and attenuation-corrected left ventricular volume measured by count method correlated with contrast ventriculographic volumes; however, attenuation corrected measurement was correlated more closely.

Additional details

Publishing Information

Journal Title
Korean Journal of Nuclear Medicine
Journal Volume
21
Journal Issue
1
Series
9 refs, 4 figs, 1 tab
Journal Page Range
p. 33-38
ISSN
1225-6714

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
41100616
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ATTENUATION; BLOOD; CORRECTIONS; HEART; PATIENTS
Descriptors DEC
BIOLOGICAL MATERIALS; BODY; BODY FLUIDS; CARDIOVASCULAR SYSTEM; MATERIALS; ORGANS