Published 1990 | Version v1
Book

Failure of Fort St. Vrain 347SS control rod drive cables

  • 1. Public Service Co. of Colorado, Denver, CO (United States)
  • 2. GA Technologies, Denver, CO (United States)

Description

This paper reports on Fort St. Vrain (FSV) which is a high temperature gas cooled reactor. During a scheduled surveillance exercise, one of the control rod drives failed to operate properly. It was found that one of the 347 austenitic stainless cables had failed at several locations and the other had a broken strand. Metallurgical examination determined that the cables failed due to chloride stress corrosion cracking. An investigation into the source of chlorides determined that materials within the core could release chlorides either by water leaching or heat up. To prevent future failures, all the stainless control cables were replaced with cables fabricated from inconel 625

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers.
Imprint Place
New York, NY (United States)
ISBN
0-7918-0506-7
Imprint Title
Fatigue, degradation, and fracture 1990
Imprint Pagination
205 p.
Journal Page Range
p. 169-174.

Conference

Title
1990 pressure vessels and piping conference.
Dates
17-21 Jun 1990.
Place
Nashville, TN (United States).

Optional Information

Secondary number(s)
CONF-900617--.