BABAR IFR Replacement R and D
Description
The Instrumented Flux Return (IFR) of the BaBar detector will soon need to be replaced by a more robust muon detection system. Scintillator bars with embedded Wavelength Shifting (WLS) fibers and Limited Streamer Tubes are two replacement technology options. The scintillator bars are tested for attenuation length; and causes for the large width of the Photo Multiplier Tube (PMT) signal are analyzed by Monte Carlo simulation. Cooling techniques for Avalanche Photo Diodes (APD) are investigated. The fairly high attenuation length coupled with the narrow PMT signal make the scintillator a viable option for a muon detecting system. Continuing work will focus on increasing timing resolution using an APD to read the signal from the WLS fibers, and investigating the lifetime of the APD. The ability to read a signal from the LST on external copper strips is tested and signals are found to be clearly distinguishable from noise. The voltage is compared to count rate to find that the optimal operating voltage for the LST used is 4600V. Further studies will be conducted in strip readout and fabrication as well as in the optimal isobutane content in the gas mixture that flows through the tube
Availability note (English)
Available from PURL: https://www.osti.gov/servlets/purl/815638-zEwinE/native/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 25 p.
- Report number
- SLAC-TN--03-008
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 34074189
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S72: PHYSICS OF ELEMENTARY PARTICLES AND FIELDS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- ATTENUATION; COMPARATOR CIRCUITS; COMPUTERIZED SIMULATION; ELECTRON MULTIPLIERS; MONTE CARLO METHOD; MULTIPARTICLE SPECTROMETERS; MUON DETECTION; OPTICAL FIBERS; PEP STORAGE RINGS; PHOSPHORS; PHOTODIODES; PHOTOMULTIPLIERS; RESOLUTION; SOLID SCINTILLATION DETECTORS
- Descriptors DEC
- CALCULATION METHODS; CHARGED PARTICLE DETECTION; DETECTION; ELECTRON TUBES; ELECTRONIC CIRCUITS; FIBERS; MEASURING INSTRUMENTS; PHOTOTUBES; RADIATION DETECTION; RADIATION DETECTORS; SCINTILLATION COUNTERS; SEMICONDUCTOR DEVICES; SEMICONDUCTOR DIODES; SIMULATION; SPECTROMETERS; STORAGE RINGS
Optional Information
- Contract/Grant/Project number
- AC03-76SF00515
- Funding organization
- USDOE Office of Science (United States)