Published September 2006
| Version v1
Report
Electronic design of electrical capacitance tomography
Creators
- 1. Malaysian Institute for Nuclear Technology Research MINT, Bangi (Malaysia). PAT Group
- 2. Universiti Teknologi Malaysia, Skudai (Malaysia)
Description
Electrical Capacitance Tomography (ECT) is a non-intrusive technique for obtaining information about the distribution of the contents of closed pipes by measuring variations in the dielectric permittivity of the material inside the pipe. The paper presents the signal conditioning circuit/electronic part of electrical capacitance tomography system, such as capacitance measurement circuit, amplifying circuit, AC to DC converter circuit and filter circuit. (Author)
Additional details
Publishing Information
- Imprint Title
- MINT R and D 2006 Seminar: compilation of papers
- Imprint Pagination
- 679 p.
- Journal Page Range
- p. 443-448
- Report number
- MINT-P--2006-4
Conference
- Title
- MINT R and D 2006 Seminar
- Dates
- 11-14 Sep 2006
- Place
- Bangi (Malaysia)
INIS
- Country of Publication
- Malaysia
- Country of Input or Organization
- Malaysia
- INIS RN
- 37113047
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CAPACITANCE; DESIGN; DIELECTRIC MATERIALS; ELECTRONIC CIRCUITS; FILTERS; PERMITTIVITY; PIPES; RECTIFIERS; SIGNAL CONDITIONING; TOMOGRAPHY; VARIATIONS
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; DIELECTRIC PROPERTIES; ELECTRICAL EQUIPMENT; ELECTRICAL PROPERTIES; EQUIPMENT; MATERIALS; PHYSICAL PROPERTIES; TUBES