Published August 2008 | Version v1
Journal article

Feasibility study of a time-resolving x-ray tomographic system

  • 1. Kramers Laboratorium voor Fysische Technologie, Delft University of Technology, Pr. Bernhardlaan 6, 2628 BW Delft (Netherlands)
  • 2. Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands)

Description

This paper discusses the possibilities for developing a tomographic scanner for studying the phase distribution of fluidized beds. The system is based on a medical x-ray source equipped with 30 CdWO4 detectors. We mimic a five-source system via simulation and in experiments of voids in a 23 fluidized bed filled with polystyrene particles. Both static voids and moving ones are studied. The reconstruction uses the simultaneous algebraic reconstruction technique with regularization. We find that it is possible to reconstruct objects with a spatial resolution of about 5 mm at a frame rate of 200 Hz. It is concluded that noise levels should be kept below 2%

Availability note (English)

Available from http://dx.doi.org/10.1088/0957-0233/19/8/085501

Additional details

Identifiers

DOI
10.1088/0957-0233/19/8/085501;
PII
S0957-0233(08)64145-4;

Publishing Information

Journal Title
Measurement Science and Technology
Journal Volume
19
Journal Issue
8
Journal Page Range
[14 p.]
ISSN
0957-0233
CODEN
MSTCEP