Evaluation of very low frequencies of ATWS and PLOHS in a loop-type FBR plant by making use of inherently safe features
- 1. Mitsubishi Atomic Power Industries, Inc., Tokyo (Japan)
- 2. Westinghouse Electric Corp., Madison, PA (USA)
Description
Frequencies of ATWS (Anticipated Transient Without Scram) and PLOHS (Protected Loss of Heat Sink) for a large loop-type FBR plant were evaluated by applying PSA methodologies. The frequencies were found to be so low that ATWS and PLOHS could be excluded from candidates of the design basis events. Furthermore, the inherently safe features introduced to the system design were verified to be very effective for reduction of the Probability of CCF (Common Cause Failure), which deteriorates reliability of both the reactor shutdown and the decay heat removal systems. (orig.)
Additional details
Publishing Information
- Publisher
- Verl. TUEV Rheinland.
- Imprint Place
- Koeln (Germany, F.R.)
- ISBN
- 3-88585-417-1
- Imprint Title
- Probabilistic safety assessment and risk management PSA '87. Vol. 2
- Imprint Pagination
- 396 p.
- Series
- Risk and safety.
- Journal Page Range
- p. 576-581.
Conference
- Title
- International topical conference on probabilistic safety assessment and risk management (PSA '87).
- Dates
- 31 Aug - 4 Sep 1987.
- Place
- Zurich (Switzerland).
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 20061286
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AFTER-HEAT REMOVAL; FBR TYPE REACTORS; PROBABILISTIC ESTIMATION; REACTOR SHUTDOWN; RISK ASSESSMENT; SAFETY
- Descriptors DEC
- BREEDER REACTORS; EPITHERMAL REACTORS; FAST REACTORS; REACTORS; SHUTDOWN