Published 2000 | Version v1
Report Open

Use of empirically based corrosion model to aid steam generator life management

Description

Alloy 800 (N08800) tubes used in CANDU 6 steam generators have shown a low incidence of corrosion damage because of the good corrosion resistance of N08800 and successful water chemistry control strategies. However, N08800 is not immune to corrosion, especially pitting, under plausible SG conditions. Electrochemical potentials are critical in determining both susceptibility and rates of corrosion and are known to be a function of water-chemistry. Using laboratory data an empirical model for pitting and crevice corrosion has been developed for N08800. Combination of such a model with chemistry monitoring and diagnostic software makes it possible to arm the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). Possible transient chemistry regimes that could significantly shorten expected tube lifetimes have been identified and predictions continue to support the position dud under normal, low dissolved oxygen conditions, pitting of N08800 will not initiate. (author)

Availability note (English)

Available from INIS in electronic form

Files

33026125.pdf

Files (249.5 kB)

Name Size Download all
md5:6b3d32ab878939411d4c7a29b38d897f
249.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
AECL--12122

Conference

Title
8. International conference on nuclear engineering (ICONE 8)
Dates
2-6 Apr 2000
Place
Baltimore, MD (United States)

Optional Information

Notes
4 refs., 1 tab., 5 figs.