Hydrogen content control system for coolant of nuclear heating plant

  • 1. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow (Russian Federation). Inst. Atomnoj Ehnergii

Description

The description of an automated system for hydrogen content control in a coolant of a nuclear heating plant (NHP), is suggested. The main elements of the system are a gas probe with the hydrogen-penetrable membrane made of the Pd-Ru alloy and the Pd-SiO2-Si solid semiconductor sensor. The system tests in the NHP loop installation of the MR reactor were made. The reliable hydrogen detection in water was shown in the range of its concentration variation from 0.2 up to 10 kg-1xcm3 at coolant temperature ≅ 170 deg C. The measurement error was not greater than 10%

Additional details

Additional titles

Original title (Russian)
Система контроля содержания водорода в теплоносителе AST

Publishing Information

Journal Title
Atomnaya Ehnergiya
Journal Volume
71
Journal Issue
3
Series
At. Ehnerg.
Journal Page Range
233-237
ISSN
0004-7163
CODEN
AENGA

INIS

Country of Publication
Russian Federation
Country of Input or Organization
USSR
INIS RN
23069744
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
ACCURACY; CONTROL SYSTEMS; COOLANTS; HYDROGEN; QUANTITATIVE CHEMICAL ANALYSIS; SEMICONDUCTOR DEVICES; SENSITIVITY; TRANSDUCERS; WATER CHEMISTRY
Descriptors DEC
CHEMICAL ANALYSIS; CHEMISTRY; ELEMENTS; NONMETALS