Description
Non-uniformity test is essentially the only required daily QC procedure in nuclear medicine practice. Noise creates statistical variation or random error in a flood image. Nonuniformity on the other hand does not have statistical nature and may be regarded as systemic error. The present methods of non-uniformity calculation do not distinguish between these two types of error. The Jarque-Bera and olmogorov-Smirnov tests were examined as alternative methods in calculation of non-uniformity in flood test images. Methods: using the Monte carol method, uniform and non-uniform flood images of different matrix sizes and count density were generated. The uniformity of the images was calculated using the present and proposed methods. The results were also tested using 1300 planar images of 128x128 matrix size. Results: the proposed methods were more accurate and sensitive to non-uniformity at low count density. However, their precision's were less than the conventional methods. There were no significant differences between these procedures at high count density. Conclusion: the integral and differential uniformity do not distinguish between noise always present in the data or in occasional non-uniformity. In a uniform intact flood image, the difference between maximum and minimum pixel count (the value of integral uniformity) is much more than recommended values for non-uniformity. After filtration of image this difference decreases but still remains high. The proposed methods are more sensitive to non-uniformity at low count density and may be used as alternative methods in daily uniformity test
Availability note (English)
Available from Atomic Energy Organization of IranAdditional details
Additional titles
- Original title (Persian)
- Barresi-ye emkan-e estefade az ravesh 'ha-ye amari dar baravord-e mayeknavakhti tasavir-e pezeshki-ye haste-ei
Publishing Information
- Journal Title
- Iranian Journal of Nuclear Medicine
- Journal Volume
- 13
- Journal Issue
- no.24
- Journal Page Range
- p. 15-24
- ISSN
- 1681-2824
INIS
- Country of Publication
- Iran, Islamic Republic of
- Country of Input or Organization
- Iran, Islamic Republic of
- INIS RN
- 37016454
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- DENSITY; EXPERIMENTAL DATA; FEASIBILITY STUDIES; MONTE CARLO METHOD; NOISE; NONUNIFORM IRRADIATION; NUCLEAR MEDICINE; QUALITY CONTROL
- Descriptors DEC
- CALCULATION METHODS; CONTROL; DATA; INFORMATION; IRRADIATION; MEDICINE; NUMERICAL DATA; PHYSICAL PROPERTIES
- Proposed descriptors and Free-text terms
- Non-uniformity test