Published August 1985 | Version v1
Report Open

Cryogenic systems for the Mirror Fusion Test Facility

Description

This paper includes an in-depth discussion of the design, fabrication, and operation of the Mirror Fusion Test Facility (MFTF) cryogenic system located at Lawrence Livermore National Laboratory (LLNL). Each subsystem discussed to present a basic composite of the entire facility. The following subsystems are included: 500kW nitrogen reliquefier, subcoolers, and distribution system; 15kW helium refrigerator/liquefier and distribution system; helium recovery and storage system; rough vacuum and high vacuum systems

Availability note (English)

Available from NTIS, PC A02; 3 as DE87008725.

Files

19000479.pdf

Files (1.1 MB)

Name Size Download all
md5:54989d6434752406355dfe8301f3cc83
1.1 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
25 p.
Report number
UCRL--93208

Conference

Title
Cryogenic engineering conference and international cryogenic materials conference.
Dates
12-16 Aug 1985.
Place
Boston, MA (USA).

Optional Information

Notes
Paper copy only, copy does not permit microfiche production.
Secondary number(s)