Published August 1985
| Version v1
Report
Open
Cryogenic systems for the Mirror Fusion Test Facility
Description
This paper includes an in-depth discussion of the design, fabrication, and operation of the Mirror Fusion Test Facility (MFTF) cryogenic system located at Lawrence Livermore National Laboratory (LLNL). Each subsystem discussed to present a basic composite of the entire facility. The following subsystems are included: 500kW nitrogen reliquefier, subcoolers, and distribution system; 15kW helium refrigerator/liquefier and distribution system; helium recovery and storage system; rough vacuum and high vacuum systems
Availability note (English)
Available from NTIS, PC A02; 3 as DE87008725.Files
19000479.pdf
Files
(1.1 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:54989d6434752406355dfe8301f3cc83
|
1.1 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 25 p.
- Report number
- UCRL--93208
Conference
- Title
- Cryogenic engineering conference and international cryogenic materials conference.
- Dates
- 12-16 Aug 1985.
- Place
- Boston, MA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19000479
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COOLING SYSTEMS; CRYOGENICS; DEWARS; GAS COMPRESSORS; HELIUM; MFTF DEVICES; NITROGEN; REFRIGERATORS; SPECIFICATIONS; SUPERCONDUCTING MAGNETS; VACUUM SYSTEMS; VAPOR CONDENSERS
- Descriptors DEC
- COMPRESSORS; CONTAINERS; ELECTRICAL EQUIPMENT; ELECTROMAGNETS; ELEMENTS; EQUIPMENT; MAGNETIC MIRRORS; MAGNETS; NONMETALS; OPEN PLASMA DEVICES; RARE GASES; SUPERCONDUCTING DEVICES; THERMONUCLEAR DEVICES
Optional Information
- Notes
- Paper copy only, copy does not permit microfiche production.
- Secondary number(s)
- CONF-850814--42.