Published November 2011 | Version v1
Report

Space radiation dosimetry-ground based verification of the MATROSHKA facility

  • 1. German Aerospace Center (DLR), Cologne (Germany)
  • 2. Vienna Univ. of Technology, Vienna (Austria)
  • 3. Inst. of Nuclear Physics, Krakow (Poland)

Description

In the framework of the MATROSHKA experiment all the proposing investigators worked together - applying different passive and active radiation detector systems - for the joint evaluation of skin and organ dose using a anthropomorphic head/torso phantom onboard the International Space Station. The first aim of the Heavy Ion Medical Accelerator in Chiba (HIMAC) Research Project is the joint irradiation of TL detectors simulating the heavy ion space radiation environment using HIMAC for TL-efficiency comparison. The second aim is the irradiation of the ground based model (phantom head) of the MATROSHKA facility equipped with passive (TLDs and Nuclear Track Etch detectors (CR-39)) as well as active radiation detectors (Silicon Scintillator Devices (SSDs)). This allows the comparison of the various detector systems directly measuring at the same time inside the phantom head. All the data will be compared with simulations applying the GEANT4 and PHITS Monte Carlo codes. (author)

Part of:
2010 annual report of the research project with heavy ions at NIRS-HIMAC

Additional details

Publishing Information

Imprint Title
2009 annual report of the research project with heavy ions at NIRS-HIMAC
Imprint Pagination
322 p.
Journal Page Range
p. 223-224
Report number
NIRS-M--244

Optional Information

Notes
This record replaces 45052152
Secondary number(s)
HIMAC--136