Published April 2016
| Version v1
Journal article
The research on matlab simulation and digital pulse shape discrimination for n-γ nuclear signal
- 1. University of South China, Hengyang (China)
Description
Neutron radiation usually mingle with γ radiation, as a result of it, the neutron signal of radiation detector usually mix γ signal. It is significant to discriminate different nuclear signal. In this study, we use matlab to simulate n-Y nuclear pulse shape digital signal and to discriminate them by pulse shape discrimination methods, then, we discuss the discrimination effect of different method. The result shows that charge comparison method, rising time method and pulse gradient analysis are all stable and reliable for n-γ discrimination, and charge comparison method is relatively better. (authors)
Additional details
Publishing Information
- Journal Title
- Chinese Journal of Nuclear Science and Engineering
- Journal Volume
- 36
- Journal Issue
- 2
- Journal Page Range
- p. 293-298
- ISSN
- 0258-0918
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 52062228
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- COMPARATIVE EVALUATIONS; M CODES; NEUTRONS; PULSE RISE TIME; PULSE SHAPERS; PULSES; RADIATION DETECTORS; RISE; SIGNALS; SIMULATION
- Descriptors DEC
- BARYONS; COMPUTER CODES; ELECTRONIC CIRCUITS; ELEMENTARY PARTICLES; EVALUATION; FERMIONS; HADRONS; MEASURING INSTRUMENTS; MODIFIED IN-SITU PROCESSES; NUCLEONS; PULSE CIRCUITS; SIGNAL CONDITIONERS; TIMING PROPERTIES
Optional Information
- Notes
- 11 figs., 1 tab., 9 refs.