Published 1976
| Version v1
Report
Open
Localization of the passage of a charged particle in a multiwire proportional chamber using electromagnetic delay line proportional chamber using electromagnetic delay line
Description
A read-out system for multi-wire proportional chambers using electromagnetic delay lines on anode and cathode planes, is described. It avoids the fitting of a circuit on each wire and presents some of the advantages of magnetostrictive detection
Availability note (English)
MF available from INIS under the Report Number.Abstract (French)
On decrit un systeme de lecture pour compteur proportionnel multifils utilisant, sur les plans cathode et anode, des lignes a retard electromagnetiques. Il evite d'equiper chaque fil d'un circuit et presente des avantages analogues a ceux de la detection magnetostrictiveFiles
8315908.pdf
Files
(188.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:e97ae776e03d245fbe35accd21058e94
|
188.0 kB | Preview Download |
Additional details
Additional titles
- Original title (French)
- Localisation du passage d'une particule chargee dans un compteur proportionnel multifils a l'aide de ligne a retard electromagnetique
Publishing Information
- Imprint Pagination
- 9 p.
- Report number
- LPC--76-12
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 8315908
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CHARGED PARTICLE DETECTION; DELAY CIRCUITS; MULTIWIRE PROPORTIONAL CHAMBER; SPECIFICATIONS
- Descriptors DEC
- ELECTRONIC CIRCUITS; MEASURING INSTRUMENTS; PROPORTIONAL COUNTERS; RADIATION DETECTION; RADIATION DETECTORS