Published July 15, 2005 | Version v1
Journal article

Nanocalorimeter fabrication procedure and data analysis for investigations on implantation damage annealing

  • 1. Regroupement Quebecois sur les Materiaux de Pointe (RQMP), Departement de physique, Universite de Montreal, C.P. 6128 succ. centre-ville, Montreal, Que., H3C 3J7 (Canada)

Description

Nanocalorimetry operates on similar principles as conventional differential thermal analysis, but the thinness of the system provides a mass addenda small enough to observe thermal processes in thin films or at surface, involving energies in the order of the nanojoules. The fabrication procedure of nanocalorimeters used to measure the heat released by damage after low-energy (30 keV) ion implantation in polycrystalline silicon (poly-Si) is described. Nanocalorimeters are fabricated from low-stress Si3N x membranes (100 nm) on which a Pt strip (25 nm) is deposited which serves both as a heater and thermometer. Using Pt allows us to carry out the metallization step prior to Si anisotropic chemical etching releasing the rectangular Si3N x membrane, so the success yield nearly reaches 100%. A 140 nm Si layer is deposited on the nanocalorimeters. Large-grain (∼75 nm) poly-Si is obtained by annealing at 900 deg C for 100 s. The calculation method used to obtain heat rate curves is described, including the corrections necessary to take into account the dissimilarity between sample and reference calorimeters (baseline), and the increased heating rate and associated losses. Examples of heat release after 30 keV Si implantations are presented, showing that the total amount of heat release is characterized by a saturation above a fluence of 1 Si-/nm2. The similarity observed in the signal shape between low and high fluence measurements also suggests that each impacting ion produces a high damage zone similar to the damage generated by high fluence irradiation. This conclusion is compatible with the annealing of damage zones proposed by molecular dynamic studies. It is also shown that the measured signal is not affected significantly by temperature non-uniformity

Additional details

Identifiers

DOI
10.1016/j.tca.2004.12.014;
PII
S0040-6031(04)00555-6;

Publishing Information

Journal Title
Thermochimica Acta
Journal Volume
432
Journal Issue
2
Journal Page Range
p. 186-191
ISSN
0040-6031
CODEN
THACAS

Conference

Title
8. Lahnwitzseminar on calorimetry
Dates
7-10 Jun 2004
Place
Rostock (Germany)

Optional Information

Copyright
Copyright (c) 2004 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.