A tokamak-type fusion machine has inherent safety associated with plasma shutdown. A small water leak can cause a plasma disruption although there is another possibility to terminate plasma without disruption. This plasma disruption will induce electromagnetic (EM) forces acting in the vacuum vessel (VV). From a radiological safety viewpoint, the VV is designed to form a physical barrier that encloses tritium and activated dust. If the VV can sustain an unstable fracture by EM forces from a through crack to cause the small leak, the structural safety will be assured and the inherent safety will be demonstrated. Therefore, a systematic approach to assure the structural safety is developed. A new analytical model to evaluate the through crack and leak rate of cooling water is proposed, with verification by experimental leak measurements. Based on the analysis, the critical crack length to terminate plasma is evaluated as about 2mm. On the other hand, the critical crack length for unstable fracture is obtained as about 400 mm. It is concluded that EM forces induced by the small leak to terminate plasma will not cause unstable fracture of the VV; thus the inherent safety is demonstrated. (author)
Additional details
Publishing Information
- Journal Title
- Journal of Nuclear Science and Technology (Tokyo)
- Journal Volume
- 41
- Journal Issue
- 2
- Journal Page Range
- p. 226-234
- ISSN
- 0022-3131
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 35031450
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CRACK PROPAGATION; CRACKING; CRACKS; ENVIRONMENTAL EFFECTS; ITER TOKAMAK; LEAK TESTING; PLASMA DISRUPTION; REACTOR VESSELS; SAFETY ANALYSIS; SCANNING ELECTRON MICROSCOPY; SURFACE TENSION; TECHNOLOGY ASSESSMENT; TEST FACILITIES
- Descriptors DEC
- CHEMICAL REACTIONS; CLOSED PLASMA DEVICES; CONTAINERS; DECOMPOSITION; ELECTRON MICROSCOPY; MICROSCOPY; PYROLYSIS; SURFACE PROPERTIES; TESTING; THERMOCHEMICAL PROCESSES; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTORS; TOKAMAK DEVICES; TOKAMAK TYPE REACTORS
Optional Information
- Notes
- 17 refs., 14 figs., 5 tabs.