Description
Injuries to the wrist are, due to its small size and complex anatomical structures, difficult to assess by MR, and surgical interventions such as diagnostic arthroscopy are often necessary. Therefore, improved visualization using non-invasive methods could be of clinical value. As a first step of improvement, the purpose of this study was to evaluate visualization of anatomical structures at 7T compared with 3T MR. Eighteen healthy volunteers (three males and three females from each age decade between 20 and 49 years) were examined with 7T and 3T MR. Four musculoskeletal radiologists graded 2D and 3D images on a five-level grading scale for visibility of ligaments, cartilage, nerves, trabecular bone, and tendons, as well as overall image quality (i.e., edge sharpness, perceived tissue contrast, and presence of artefacts). Statistical analysis was done using a visual grading characteristics (VGC) analysis. Visibility of cartilage, trabecular bone, tendons, nerves, and ligaments was graded significantly higher at 7T with an area under the curve (AUC) of 0.62-0.88 (95% confidence interval [CI] 0.50-0.97, p = < 0.0001-0.03) using either 2D or 3D imaging. Imaging with 3T was not graded as superior to 7T for any structure. Image quality was also significantly superior at 7T, except for artefacts, where no significant differences were found. Tendons, trabecular bone, nerves, and ligaments were all significantly better visualized at 7T compared to 3T. MRI of the wrist at 7T with a commercially available wrist coil is feasible at similar acquisition times as for 3T MRI. The current study showed 7T to be superior to 3T in the visualization of anatomical structures of the wrist, including ligaments, tendons, nerves, and trabecular bone. Image quality was significantly superior at 7T, except for artefacts, where no significant differences were found.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-021-08165-5Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 32
- Journal Issue
- 2
- Journal Page Range
- p. 1362-1370
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 53030406
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AGE GROUPS; ANATOMY; BONE JOINTS; CARTILAGE; COMPARATIVE EVALUATIONS; HANDS; IMAGE PROCESSING; IMAGE SCANNERS; INJURIES; LIGAMENTS; MAGNETIC FIELDS; NERVES; NMR IMAGING; PROTON DENSITY; RELAXATION TIME; SURGERY; TENDONS; TRABECULAR BONE; WEIGHTING FUNCTIONS
- Descriptors DEC
- ANIMAL TISSUES; ARMS; BIOLOGY; BODY; BONE TISSUES; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; FUNCTIONS; LIMBS; MEDICINE; NERVOUS SYSTEM; ORGANS; PROCESSING; SKELETON