Published June 2023 | Version v1
Journal article

A research on the removal of radioactive pollutants from metal surface by means of Ce (IV)/HNO3 decontamination technology

  • 1. University of South China, Hunan (China). School of Nuclear Science and Technology
  • 2. The Affiliated Hospital of Guizhou Medical University, Guizhou (China). Nuclear Medicine Department

Description

A decontamination study of iodine-131 contamination by Ce (IV)/HNO3 was carried out using orthogonal tests for radioactive contamination of metal surfaces. The effects of nitric acid concentration, Ce (IV) concentration, temperature, and decontamination time on the decontamination factors of brass and aluminum were obtained. The maximum value of decontamination factor was 5.80 for brass: temperature was approximately equal to Ce (IV) concentration than decontamination time than nitric acid concentration, and the maximum value of decontamination factor was 319.49 for aluminum: Ce (IV) concentration than decontamination time than nitric acid concentration than temperature. (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
332
Journal Issue
6
Journal Page Range
p. 2349-2357
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
31 refs.