Ventricular fibrillation time constant for swine

  • 1. Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI 53706 (United States)
  • 2. Department of Biomedical Engineering, University of Wisconsin, 1550 Engineering Drive, Madison, WI 53706 (United States)
  • 3. Department of Surgery, University of Wisconsin, Madison, WI 53792 (United States)
  • 4. Department of Nutritional Sciences, University of Wisconsin, Madison, WI 53706 (United States)
  • 5. Departments of Pathobiology, SVM, and Animal Sciences, CALS, University of Wisconsin, Madison, WI 53706 (United States)

Description

The strength–duration curve for cardiac excitation can be modeled by a parallel resistor–capacitor circuit that has a time constant. Experiments on six pigs were performed by delivering current from the X26 Taser dart at a distance from the heart to cause ventricular fibrillation (VF). The X26 Taser is an electromuscular incapacitation device (EMD), which generates about 50 kV and delivers a pulse train of about 15–19 pulses s−1 with a pulse duration of about 150 µs and peak current about 2 A. Similarly a continuous 60 Hz alternating current of the amplitude required to cause VF was delivered from the same distance. The average current and duration of the current pulse were estimated in both sets of experiments. The strength–duration equation was solved to yield an average time constant of 2.87 ms ± 1.90 (SD). Results obtained may help in the development of safety standards for future electromuscular incapacitation devices (EMDs) without requiring additional animal tests

Availability note (English)

Available from http://dx.doi.org/10.1088/0967-3334/29/10/005

Additional details

Identifiers

DOI
10.1088/0967-3334/29/10/005;
PII
S0967-3334(08)76553-5;

Publishing Information

Journal Title
Physiological Measurement (Print)
Journal Volume
29
Journal Issue
10
Journal Page Range
p. 1209-1219
ISSN
0967-3334

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44127320
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
ALTERNATING CURRENT; EQUIPMENT; EXCITATION; HEART; PULSES; SAFETY STANDARDS; SWINE; TESTING
Descriptors DEC
ANIMALS; BODY; CARDIOVASCULAR SYSTEM; CURRENTS; DOMESTIC ANIMALS; ELECTRIC CURRENTS; ENERGY-LEVEL TRANSITIONS; MAMMALS; ORGANS; STANDARDS; VERTEBRATES