Performance of a directly-coupled PV water pumping system
- 1. Faculty of Science, University of Science and Technology, Oran 31000 (Algeria)
- 2. Power Electronics and Solar Energy Laboratory, University of Science and Technology, Oran (Algeria)
- 3. Electronic Microscopy and Material Science Laboratory, University of Science and Technology, Oran (Algeria)
- 4. Department of Environmental Sciences, COMSATS Institute of Information Technology, Abbottabad (Pakistan)
Description
Highlights: → Directly coupled PV water pumping system installed and performance studied. → Configured for two static heads, operate without electronic control and auxiliary power. → The system attains steady state soon after any abrupt change. → Cost effective and useful for low head communicating wells system. - Abstract: This paper describes the experimental study carried out to investigate the performance of a simple, directly coupled dc photovoltaic (PV) powered water pumping system. The system comprises of a 1.5 kWp PV array, dc motor and a centrifugal pump. The experiment was conducted over a period of 4 months and the system performance was monitored under different climatic conditions and varying solar irradiance with two static head configurations. Although the motor-pump efficiency did not exceed 30%, which is typical for directly-coupled photovoltaic pumping systems, such a system is clearly suitable for low head irrigation in the remote areas, not connected to the national grid and where access to water comes as first priority issue than access to technology. The system operates without battery and complex electronic control, therefore not only the initial cost is low but also maintenance, repairing and replacement cost can be saved. The study showed that directly coupled system attains steady state soon after any abrupt change.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.enconman.2011.04.024Additional details
Identifiers
- DOI
- 10.1016/j.enconman.2011.04.024;
- PII
- S0196-8904(11)00154-3;
Publishing Information
- Journal Title
- Energy Conversion and Management
- Journal Volume
- 52
- Journal Issue
- 10
- Journal Page Range
- p. 3089-3095
- ISSN
- 0196-8904
- CODEN
- ECMADL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43069296
- Subject category
- S42: ENGINEERING; S29: ENERGY PLANNING, POLICY AND ECONOMY;
- Descriptors DEI
- CENTRIFUGAL PUMPS; COST; MAINTENANCE; MOTORS; PERFORMANCE; PHOTOVOLTAIC EFFECT; PUMPING; REMOTE AREAS; STEADY-STATE CONDITIONS; WATER
- Descriptors DEC
- ENGINES; EQUIPMENT; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; PHOTOELECTRIC EFFECT; PUMPS
Optional Information
- Copyright
- Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.