Published 1998 | Version v1
Book

Assessment of physical protection systems of nuclear power plants

  • 1. Nuclear Regulatory Authority, Buenos Aires (Argentina)

Description

The Argentinian Nuclear Regulatory Authority has developed a computerized model called 'IntruBuster', version 2.0, to evaluate the physical protection system of nuclear installations. This evaluation is performed through a graphic model of the installations, including information about the distribution of different sectors, detection elements, decay elements, modality of intruder access and security force response time. (author)

Part of:
Physical protection of nuclear materials: Experience in regulation, implementation and operations. Proceedings of a conference

Additional details

Publishing Information

Publisher
IAEA
Imprint Place
Vienna (Austria)
ISBN
92-0-101398-1
Imprint Title
Physical protection of nuclear materials: Experience in regulation, implementation and operations. Proceedings of a conference
Imprint Pagination
527 p.
Series
Proceedings series
Journal Page Range
p. 237-245
ISSN
0074-1884

Conference

Title
Experience in regulation, implementation and operations
Acronym
Conference on physical protection of nuclear materials
Dates
10-14 Nov 1997
Place
Vienna (Austria)

INIS

Country of Publication
Austria
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
29046669
Subject category
S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ARGENTINA; COMPUTER GRAPHICS; COMPUTERIZED SIMULATION; MONTE CARLO METHOD; NUCLEAR FACILITIES; PHYSICAL PROTECTION; RISK ASSESSMENT
Descriptors DEC
CALCULATION METHODS; DEVELOPING COUNTRIES; LATIN AMERICA; SIMULATION; SOUTH AMERICA

Optional Information

Notes
3 figs
Secondary number(s)
IAEA-CN--68/2