Published July 1987 | Version v1
Journal article

MR image synthesis using multiple spin echoes

  • 1. Osaka Univ. (Japan). Faculty of Medicine

Description

A new method of spin echo image synthesis is reported. This method uses a combination of multiple spin echo image trains as source images. The combination and the coefficient of the source image are essential to determine both the TE and the quality of the synthesized image. The coefficient is arbitrarily specified by the operator and is used in the image processing. T2 calculation is not prerequisite to the process. Some of the synthesized images exhibit higher S/N ratios than the original ones representing the same TE. The images at arbitrary TE are able to be formed by this method as well as previously reported methods. But the images for TRs different from that used to acquire the source images cannot be produced, because there isn't enough T1-information in the sources. (author)

Additional details

Publishing Information

Journal Title
Nippon Igaku Hoshasen Gakkai Zasshi
Journal Volume
47
Journal Issue
7
Series
Nippon Igaku Hoshasen Gakkai Zasshi.
Journal Page Range
983-988
ISSN
0048-0428
CODEN
NHGZA

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
19013027
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
IMAGE PROCESSING; IMAGES; NMR IMAGING; PHANTOMS; SPIN ECHO; SPIN-SPIN RELAXATION
Descriptors DEC
DIAGNOSTIC TECHNIQUES; MOCKUP; RELAXATION; STRUCTURAL MODELS