Published October 1, 2000 | Version v1
Journal article

Measurement of 15 MeV γ-rays with the Ge cluster detectors of EUROBALL

Description

A measurement of the response to 15.1 MeV γ-rays has been made for the Ge cluster detectors in the EUROBALL array. Each cluster detector consists of seven germanium capsules surrounded by a single anticompton shield of BGO. The reaction D(11B,γ)12C+n at Ebeam=19.1 MeV has been employed. The 'adding-back' of signals simultaneously present in the capsules composing each cluster detector has been made on an event by event basis. The intensity in full-energy peak increases by a factor of three as compared to that of the spectrum obtained by summing the individual spectra of the 7 capsules. The pulse height to energy conversion is found to be very linear from few hundreds keV to 15 MeV. The efficiency is discussed relative to that of large volume BaF2 scintillators

Additional details

Identifiers

PII
S0168900200004447;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
452
Journal Issue
3
Journal Page Range
p. 422-430
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2000 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.