Published March 1982 | Version v1
Journal article

Radiation exposure reduction using carbon fiber

Creators

  • 1. Department of Radiology, University of Miami School of Medicine, Miami, FL

Description

The ability of carbon fiber cassette fronts to reduce x-ray exposure was evaluated by comparing a carbon fiber cassette with a Kodak X-Omatic cassette. Rare-earth screens were used. Although the transmission of the carbon fiber was considerably higher than that of the X-Omatic cassette, the radiation exposure reduction was significant only in the lower kVp ranges. Although some decrease in the primary-to-scatter ratio was measured, the overall image contrast with the carbon fiber cassette was only minimally reduced in the kVp range investigated

Additional details

Publishing Information

Journal Title
Radiology
Journal Volume
142
Journal Issue
3
Series
Radiology.
Journal Page Range
751-754
ISSN
0033-8419

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
14728207
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; CARBON; FIBERS; PATIENTS; RADIATION DOSES; RARE EARTHS; X RADIATION; X-RAY EQUIPMENT
Descriptors DEC
DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; ELEMENTS; EQUIPMENT; IONIZING RADIATIONS; MEDICINE; METALS; NONMETALS; RADIATIONS